| 1889 - 454 páginas
...must be uncovered for inspection. 11. — No brick, sheet metal, earthenware or chimney flue shall bo used as a sewer ventilator, nor to ventilate any trap, drain, soil or waste pipe. 12. — Every soil pipe shall be of cast iron of the weight specified in Section 20, and... | |
| William R. Maguire - 1890 - 460 páginas
...cold-air box for a furnace shall be so placed that it can possibly draw air from this inlet pipe. 16. No brick, sheet metal, earthenware, or chimney flue...ventilator, nor to ventilate any trap, drain, soil, or waste pipe. 17. Every vertical soil and main waste pipe must be of iron, and where it receives the... | |
| 1890 - 676 páginas
...properly fitted and made gas and air-tight with some proper cement. RULE 11. No brick, sheet-metal, earthen-ware or chimney flue shall be used as a sewer...to ventilate any trap, drain, soil or waste-pipe. RULE 12. Every soil and waste-pipe must be of cast iron, lapwelded wrought iron, lead, copper or brass,... | |
| Cady Staley - 1891 - 318 páginas
...trap. Wash-rooms for carriages must be provided with proper means for intercepting mud. VENT-PIPES. SEC. 23. Traps must be protected from syphonage, or...by a special pipe not directly connected with any wastepipe, soil-pipe or sewer. The drip pipe from refrigerators shall not be connected directly with... | |
| Cady Staley, George Spencer Pierson - 1891 - 314 páginas
...trap. Wash-rooms for carriages must be provided with proper means for intercepting mud. VENT-PIPES. SEC. 23. Traps must be protected from syphonage, or...trap, drain, soil or waste-pipe. SAFES — RAIN WATER. SBC. 24. Every lead safe under a wash-tray, urinal, refrigerator or water closet must be drained by... | |
| Maine. State Board of Health - 1891 - 338 páginas
...properly fitted and made gas and air-tight with some proper cement. RULE 11. No brick, sheet-metal, earthen-ware or chimney flue shall be used as a sewer...to ventilate any trap, drain, soil or waste-pipe. RULE 12. Every soil and waste-pipe must be of cast iron, lapwelded wrought iron, lead, copper or brass,... | |
| Maine. State Board of Health - 1891 - 336 páginas
...properly fitted and made gas and air-tight with some proper cement. RULE 11. No brick, sheet-metal, earthen-ware or chimney flue •shall be used as a...to ventilate any trap, drain, soil or waste-pipe. RUIE 12. Every soil and waste-pipe must be of cast iron, lapwelded wrought iron, lead, copper or brass,... | |
| Alfred Revill - 1894 - 238 páginas
...furnace shall be so placed that it can possibly draw air from this inlet pipe. 21. No brick, sheet-metal, earthenware, or chimney flue shall be used as a sewer...ventilator, nor to ventilate any trap, drain, soil, or waste pipe. 22. Every vertical soil, waste, and vent pipe must be of extra heavy iron pipe. Where soil... | |
| Ohio. Department of Health - 1897 - 782 páginas
...horizontal pipes shall be made with Y branches or sanitary T's. No brick, sheet metal, earthen ware or chimney flue shall be used as a sewer ventilator, nor to ventilate any trap, drain, soil or waste pipe. SKC. 21. All cast iron soil, waste or vent pipeS, before they are connected, must be thoroughly... | |
| 1897 - 470 páginas
...horizontal pipes shall be made with Y branches or sanitary T's. No brick, sheet metal, earthen ware or chimney flue shall be used as a sewer ventilator, nor to ventilate any trap, drain, soil or waste pipe. SEC. 21. All cast iron soil, waste or vent pipes, before they are connected, must be thoroughly... | |
| |