Report A-[F] of Commission on Electric Lighting for the City of New York ...: Submitted to the Board of Estimate and Apportionment. Commission: Cary T. Hutchinson, Chairman ...1906 |
Dentro del libro
Resultados 1-5 de 62
Página 37
... Roofing . 60. Windows , Doors and Carpentry . 61. Glass . 62. Painting . 63. Ornamental Iron . 64. Marble . 65. Plumbing . 66. Chimneys . 67. Extra Material . 43. General Description , Grades . SECTION II . FOUNDATIONS 37.
... Roofing . 60. Windows , Doors and Carpentry . 61. Glass . 62. Painting . 63. Ornamental Iron . 64. Marble . 65. Plumbing . 66. Chimneys . 67. Extra Material . 43. General Description , Grades . SECTION II . FOUNDATIONS 37.
Página 38
... roof . A basement is to be provided under boiler room , turbine room and wings . ( b ) A coal handling and storage plant is to be located between the Power House Building and the East River . ( c ) One intake and one discharge condenser ...
... roof . A basement is to be provided under boiler room , turbine room and wings . ( b ) A coal handling and storage plant is to be located between the Power House Building and the East River . ( c ) One intake and one discharge condenser ...
Página 39
... roof charge tunnels ( at east wall of Power House ) Inside top of intake and discharge tunnels ( at east wall of Power House ) Basement in pavilions Roadway through basement 66 -16.0 66 66 -8.0 10.0 66 7.5 ( a ) The excavation shall be ...
... roof charge tunnels ( at east wall of Power House ) Inside top of intake and discharge tunnels ( at east wall of Power House ) Basement in pavilions Roadway through basement 66 -16.0 66 66 -8.0 10.0 66 7.5 ( a ) The excavation shall be ...
Página 50
... roofing , face work of structure and other masonry constructions as are herein described or shown on the plans and as are located above a datum line established four ( 4 ) inches below the sidewalk or area way levels for exterior walls ...
... roofing , face work of structure and other masonry constructions as are herein described or shown on the plans and as are located above a datum line established four ( 4 ) inches below the sidewalk or area way levels for exterior walls ...
Página 51
... roof trusses , roof framing , coal pocket , supports for boilers and for coal weighing hoppers , string- ers for conveyor runs , lintels , anchor bolts , anchor and bearing plates and all bracing and accessories . ( b ) The Contractor ...
... roof trusses , roof framing , coal pocket , supports for boilers and for coal weighing hoppers , string- ers for conveyor runs , lintels , anchor bolts , anchor and bearing plates and all bracing and accessories . ( b ) The Contractor ...
Otras ediciones - Ver todas
Report A-[F] of Commission on Electric Lighting for the City of New York ... New York (N y ) Commission on Electric L Sin vista previa disponible - 2015 |
Términos y frases comunes
000 kilowatt-hours 000 kilowatts approved arc lamps arc lights basement floor blow-off boiler feed pumps boiler room Boroughs brass Bronx Brooklyn Brooklyn and Queens bulkhead busbars capacity cast iron cement central station cents City clean coal bunkers COMMISSION ON ELECTRIC Commissioner complete concrete condenser connected construction contract Contractor copper diameter doors drawings duct ELECTRIC LIGHTING Engineer equipment estimate extra heavy face brick feeders feet finished fittings flanges flue furnished galvanized gate valves grade incandescent lighting incandescent service inch intake iron pipe iron pipe size joints load located Manhattan masonry material mortar necessary nickel plated oil switches operating plant plaster plumbing Portland cement Power House pressure public buildings Report Richmond roof sash seawall specifications steam stone storage streets structural steel sub-stations superheater supply surface surge tank thick tile tion total annual cost total cost wall water closet wattmeter wrought iron York
Pasajes populares
Página 33 - ... in case of such discontinuance of the employment of the contractor he shall not be entitled to receive any further payment under this contract until the said work shall be wholly finished, at which time, if the unpaid balance of the amount to be paid under this contract shall exceed the expense Incurred by the owner in finishing the work, such excess shall be paid by the owner to the contractor...
Página 33 - ... written notice to the contractor, to provide any such labor or materials, and to deduct the cost thereof from any money then due or thereafter to become due to the contractor under...
Página 33 - Should the Contractor at any time refuse or neglect to supply a sufficiency of properly skilled workmen, or of materials of the proper quality, or fail in any respect to prosecute the work wIth promptness and diligence, or fail in the performance of any of the agreements herein contained, such refusal, neglect or failure being certified by the Architects, the Owner shall be at liberty, after three days...
Página 10 - DOLLAKS for each and every day the time consumed in said performance and completion may exceed the time hereinbefore allowed for that purpose; which said sum, in view of the difficulty of ascertaining the loss which The...