Página 85
... valve of extra strong proportions with re- ducing valve , pressure gauge and safety valve . ( e ) Water Supply . - All supply pipe for hot and cold water is to be extra heavy , and of the best American lap - welded galvanized wrought ...
... valve of extra strong proportions with re- ducing valve , pressure gauge and safety valve . ( e ) Water Supply . - All supply pipe for hot and cold water is to be extra heavy , and of the best American lap - welded galvanized wrought ...
Página 86
... valve the full diameter of the pipe and under each fixture place a gate valve for controlling the same ; all pipes to have proper air vents , so grad- ed that they can be emptied in drain trenches in basement and to have cocks for that ...
... valve the full diameter of the pipe and under each fixture place a gate valve for controlling the same ; all pipes to have proper air vents , so grad- ed that they can be emptied in drain trenches in basement and to have cocks for that ...
Página 88
... valves , these to be set in iron valve boxes . Brass valves are to be provided on the mains at the meters and otherwise as may be required to conveniently control the various parts of the system . ( 0 ) Water Closets . For the purpose ...
... valves , these to be set in iron valve boxes . Brass valves are to be provided on the mains at the meters and otherwise as may be required to conveniently control the various parts of the system . ( 0 ) Water Closets . For the purpose ...
Página 94
... Valves and Flanges . 94. Main Steam and Auxiliary Lines . 95. Atmospheric Exhausts . 96. Condenser Piping . 97. Auxiliary Exhaust Piping . 98. Cold and Hot Water Piping . 99. Oiling System . 100. Blow - Off Piping . 101. Exciters . 102 ...
... Valves and Flanges . 94. Main Steam and Auxiliary Lines . 95. Atmospheric Exhausts . 96. Condenser Piping . 97. Auxiliary Exhaust Piping . 98. Cold and Hot Water Piping . 99. Oiling System . 100. Blow - Off Piping . 101. Exciters . 102 ...
Página 96
... valve and a protecting gate valve or plug cock of approved design and manufacture . Each boiler shall be fitted with a pressure gauge and two independent single glass water columns with extra heavy bronze gate valves for shutting off ...
... valve and a protecting gate valve or plug cock of approved design and manufacture . Each boiler shall be fitted with a pressure gauge and two independent single glass water columns with extra heavy bronze gate valves for shutting off ...
Otras ediciones - Ver todas
Report A-[F] of Commission on Electric Lighting for the City of New York ... New York (N y ) Commission on Electric L Sin vista previa disponible - 2015 |
Términos y frases comunes
000 kilowatt-hours 000 kilowatts approved arc lamps arc lights basement floor blow-off boiler feed pumps boiler room Boroughs brass Bronx Brooklyn Brooklyn and Queens bulkhead busbars capacity cast iron cement central station cents City clean coal bunkers COMMISSION ON ELECTRIC Commissioner complete concrete condenser connected construction contract Contractor copper diameter doors drawings duct ELECTRIC LIGHTING Engineer equipment estimate extra heavy face brick feeders feet finished fittings flanges flue furnished galvanized gate valves grade incandescent lighting incandescent service inch intake iron pipe iron pipe size joints load located Manhattan masonry material mortar necessary nickel plated oil switches operating plant plaster plumbing Portland cement Power House pressure public buildings Report Richmond roof sash seawall specifications steam stone storage streets structural steel sub-stations superheater supply surface surge tank thick tile tion total annual cost total cost wall water closet wattmeter wrought iron York
Pasajes populares
Página 33 - ... in case of such discontinuance of the employment of the contractor he shall not be entitled to receive any further payment under this contract until the said work shall be wholly finished, at which time, if the unpaid balance of the amount to be paid under this contract shall exceed the expense Incurred by the owner in finishing the work, such excess shall be paid by the owner to the contractor...
Página 33 - ... written notice to the contractor, to provide any such labor or materials, and to deduct the cost thereof from any money then due or thereafter to become due to the contractor under...
Página 33 - Should the Contractor at any time refuse or neglect to supply a sufficiency of properly skilled workmen, or of materials of the proper quality, or fail in any respect to prosecute the work wIth promptness and diligence, or fail in the performance of any of the agreements herein contained, such refusal, neglect or failure being certified by the Architects, the Owner shall be at liberty, after three days...
Página 10 - DOLLAKS for each and every day the time consumed in said performance and completion may exceed the time hereinbefore allowed for that purpose; which said sum, in view of the difficulty of ascertaining the loss which The...